SOCLA M & MI Systems

SOCLA's M and MI Systems offer membrane non-return valves designed for installations susceptible to water hammer, providing silent and reliable backflow prevention. The flexible elastomer membranes ensure progressive opening and effective sealing, resulting in low head loss. These valves are suitable for booster pumps, sprinkler systems, and compressed air circuits, operating at pressures up to 16 bar and temperatures from -10°C to 60°C. Compliant with EN 1092-2 and PED 2014/68/UE standards, they support both flanged and threaded connections, ensuring versatile application across various systems.

SOCLA 207 Membrane Check Valves

Boosting Units, Vacuum Pumps, & Compressed Air

The SOCLA 207 Membrane Check Valves are designed for systems prone to significant water hammer, offering quiet operation with no moving mechanical parts. Suitable for booster pumps, compressed air circuits, and variable flow applications, they feature a self-closing membrane for reliable sealing and minimal head loss. With an operating range of -10°C to 60°C, these valves support female BSP connections and comply with ISO 228 standards for clear liquids and gases.

 Technical Datasheet 

Pressure: PFA 16 Bar
Size Range: 12 ... 90 mm
Body Materials: EPDM, Aluminium, Cast Iron, Epoxy, Stainless Steel, Brass, NR, & Galvanised Steel
Approvals: CE Marking, & BVERITAS
Weight Range (KG): 0.15 ... 12.00
Enquire Here

SOCLA 207V Membrane Check Valves

Industrial Services, Compressed Air, Vacuum Pimps, & Hydrocarbons

The SOCLA 207V Membrane Check Valve is designed to provide silent and reliable backflow prevention in systems prone to water hammer. Its flexible elastomer membrane ensures progressive opening, low head loss, and effective sealing. Suitable for booster pumps, sprinkler systems, and compressed air circuits, it operates at pressures up to 16 bar and temperatures from -10°C to 100°C. Supporting BSP threaded connections, it complies with PED 2014/68/UE standards and operates in any position.

 Technical Datasheet 

Pressure: PFA 16 Bar
Size Range: 12 ... 90 mm
Body Materials: FKM, Aluminium, Cast Iron, Epoxy, Stainless Steel, Brass, & Galvanised Steel
Approvals: CE Marking, & BVERITAS
Weight Range (KG): 0.15 ... 12.00
Enquire Here

SOCLA 317 Membrane Check Valves

Irrigation, & Limited Working Pressure

The SOCLA 317 Membrane Foot Valve provides reliable backflow prevention and is particularly suited for variable flow pumps and pulsatory operations. Its flexible EPDM membrane ensures progressive opening, low head loss, and effective sealing against the cylindrical seat. Operating at pressures up to 6 bar and temperatures from -10°C to 60°C, it is compatible with sleeve connections ranging from DN 40 to 300 mm. Compliant with PED 2014/68/UE standards, it supports clear liquids in demanding systems.

 Technical Datasheet 

Pressure: PFA 6 Bar
Size Range: 30 ... 276 mm
Body Materials: Cast Iron, Epoxy, EPDM, Galvanised Steel, & Copper
Approvals: ACS
Weight Range (KG): 1.78 ... 67.90
Enquire Here

SOCLA 327 Membrane Check Valves

Irrigation, & Limited Working Pressure

The SOCLA 327 Membrane Foot Valve ensures reliable backflow prevention and is ideal for variable flow pumps and pulsatory operations. Featuring a flexible EPDM tubular membrane, it provides low head loss, silent operation, and effective sealing against a cylindrical seat. Operating at pressures up to 6 bar and temperatures from -10°C to 60°C, it supports flanged connections and clear or sandy liquids. Compliant with EN 1092-2 and PED 2014/68/UE standards, it suits diverse industrial applications.

 Technical Datasheet 

Pressure: PFA 6 Bar
Size Range: 50 ... 300 mm
Body Materials: Cast Iron, Epoxy, EPDM, Galvanised Steel, & Copper
Approvals: ACS
Weight Range (KG): 3.15 ... 63.60
Enquire Here

SOCLA 337 Membrane Check Valves

Irrigation, & Limited Working Pressure

The SOCLA 337 Membrane Check Valve provides reliable backflow prevention for variable flow pumps and pulsatory operations. It features a flexible EPDM tubular membrane that ensures low head loss and effective sealing against the cylindrical seat. Suitable for clear and slightly loaded liquids, it operates at pressures up to 6 bar and temperatures from 0°C to 60°C. With BSP and NPT threaded connections, it complies with PED 2014/68/UE standards, supporting efficient and silent operation.

 Technical Datasheet 

Pressure: PFA 6 Bar
Size Range: 50 ... 100 mm
Body Materials: Cast Iron, Epoxy, EPDM, Galvanised Steel, & Copper
Approvals: ACS
Weight Range (KG): 1.88 ... 5.65
Enquire Here

SOCLA 407 Membrane Check Valves

Boosting Units, Vacuum Pumps, & Compressed Air

The SOCLA 407 Membrane Check Valve provides reliable backflow prevention, ideal for installations prone to water hammer. Its flexible elastomer membrane ensures silent operation, low head loss, and efficient sealing. Operating at pressures up to 16 bar and temperatures from -10°C to 60°C, it is suitable for booster pumps, sprinkler systems, and compressed air circuits. Constructed with an epoxy-coated cast iron body and stainless steel components, it complies with EN1092-2 and PED 2014/68/UE standards.

 Technical Datasheet 

Pressure: PFA 10 ... 16 Bar
Size Range: 40 ... 200 mm
Body Materials: FKM, Cast Iron, Epoxy, Stainless Steel, Rilsan Coated Steel, Brass, FKM, & Galvanised Steel
Approvals: CE Marking, & BVERITAS
Weight Range (KG): 6.9 ... 81.6
Enquire Here

SOCLA 407B Membrane Check Valves

Boosting Units, Vacuum Pumps, & Compressed Air

The SOCLA 407B Membrane Check Valve offers effective backflow prevention with a flexible elastomer membrane that provides silent operation, progressive opening, and reliable sealing. Designed for systems prone to water hammer, it is suitable for booster pumps, compressed air circuits, and vacuum systems. Operating at pressures up to 16 bar and temperatures from -10°C to 60°C, it supports flanged connections and complies with EN 1092-2 and PED 2014/68/UE standards.

 Technical Datasheet 

Pressure: PFA 10 ... 16 Bar
Size Range: 40 ... 200 mm
Body Materials: EPDM, Cast Iron, Epoxy, Stainless Steel, Coated Steel Rilsan, Brass, & NR
Approvals: CE Marking, & BVERITAS
Weight Range (KG): 7 ... 81.7
Enquire Here

SOCLA 407RR Membrane Check Valves

Thermal Water, & Aggressive Liquids

The SOCLA 407RR Membrane Check Valve offers efficient backflow prevention with a flexible elastomer membrane for silent operation and low head loss. Designed to reduce water hammer, it operates at pressures up to 16 bar and temperatures from -10°C to 60°C. Ideal for booster pumps, sprinkler systems, and compressed air circuits, it features a Rilsan-coated cast iron body and complies with EN1092-2 and PED 2014/68/UE standards, ensuring reliable performance in demanding applications.

 Technical Datasheet 

Pressure: PFA 10 ... 16 Bar
Size Range: 40 ... 200 mm
Body Materials: EPDM, Rilsan Coated Cast Iron, Stainless Steel, Brass, NR, & Galvanised Steel
Approvals: CE Marking, & BVERITAS
Weight Range (KG): 6.9 ... 81.60
Enquire Here

SOCLA 407V Membrane Check Valves

Industrial Services, Compressed Air, Vacuum Pimps, & Hydrocarbons

The SOCLA 407V Membrane Check Valve is ideal for installations prone to water hammer, offering quiet and efficient backflow prevention. Its flexible elastomer membrane provides progressive opening and reliable sealing, reducing head loss. Suitable for booster pumps, sprinkler systems, and compressed air circuits, it operates at pressures up to 16 bar and temperatures from -10°C to 100°C. Compliant with EN1092-2 and PED 2014/68/UE standards, it supports horizontal and vertical installations.

 Technical Datasheet 

Pressure: PFA 10 ... 16 Bar
Size Range: 40 ... 200 mm
Body Materials: FKM, Cast Iron, Epoxy, Stainless Steel, Polyamide Coated Steel, Brass, & Galvanised Steel
Approvals: CE Marking
Weight Range (KG): 6.9 ... 81.6
Enquire Here

SOCLA 417 Membrane Check Valves

Boosting Units, Vacuum Pumps, & Compressed Air

The SOCLA 417 Membrane Check Valves are designed to handle significant water hammer in booster pumps, compressed air circuits, and vacuum pumps. These valves feature a flexible elastomer membrane for self-closing, ensuring reliable sealing, quiet operation, and minimal head loss. Suitable for clear liquids and gases, they operate at temperatures from -10°C to 60°C and comply with EN 1092-2 flange drilling standards, supporting installations in any position.

 Technical Datasheet 

Pressure: PFA 25 Bar
Size Range: 40 ... 150 mm
Body Materials: EPDM, Cast Iron, Epoxy, Stainless Steel, Brass, EPDM, & Galvanised Steel
Approvals: ACS, CE Marking, & BVERITAS
Weight Range (KG): 7.2 ... 44.0
Enquire Here

SOCLA 447 Membrane Check Valves

Industrial Services, Compressed Air, Vacuum Pimps, & Hydrocarbons

The SOCLA 447 Membrane Check Valve is designed for systems prone to water hammer, ensuring quiet and reliable backflow prevention. It features a self-closing elastomer membrane for low head loss and efficient sealing, operating at pressures up to 16 bar and temperatures from -10°C to 60°C. Suitable for clear liquids and gases, it supports flanged connections and complies with EN 1092-2 and PED 2014/68/UE standards. Ideal for booster pumps and variable flow systems, it offers durable and silent operation.

 Technical Datasheet 

Pressure: PFA 10 ... 16 Bar
Size Range: 65 ... 200 mm
Body Materials: EPDM, Cast Iron, Epoxy, Stainless Steel, Steel, Polyamide, Brass, NR & Galvanised Steel
Approvals: CE Marking
Weight Range (KG): 11.9 ... 87.3
Enquire Here

SOCLA 447B Membrane Check Valves

Boosting Units, Vacuum Pumps, & Compressed Air

The SOCLA 447B Membrane Check Valve offers efficient backflow prevention, designed for systems prone to water hammer. Featuring a flexible elastomer membrane, it ensures silent operation, progressive opening, and effective sealing with minimal head loss. Ideal for booster pumps, sprinkler systems, and compressed air circuits, it operates at pressures up to 16 bar and temperatures from -10°C to 60°C. It supports flanged connections and complies with EN1092-2 and PED 2014/68/UE standards.

 Technical Datasheet 

Pressure: PFA 10 ... 16 Bar
Size Range: 65 ... 200 mm
Body Materials: EPDM, Cast Iron, Epoxy, Stainless Steel, Brass, NR, & Galvanised Steel
Approvals: CE Marking
Weight Range (KG): 11.9 ... 87.3
Enquire Here

SOCLA 447RR Membrane Check Valves

Booster Pumps, Compressed Air Circuits, & Vacuum Pumps

The SOCLA 447RR Membrane Check Valve provides effective backflow prevention, ideal for installations prone to water hammer. Its flexible elastomer membrane ensures silent operation, progressive opening, and reliable sealing with minimal head loss. Operating at pressures up to 16 bar and temperatures from -10°C to 60°C, it is suitable for booster pumps, sprinkler systems, and compressed air circuits. Compliant with EN1092-2 and PED 2014/68/UE standards, it supports flanged connections.

 Technical Datasheet 

Pressure: PFA 10 ... 16 Bar
Size Range: 65 ... 200 mm
Body Materials: EPDM, Polyamide Coated Cast Iron, Stainless Steel, Brass, NR, & Galvanised Steel
Approvals: CE Marking, & BVERITAS
Weight Range (KG): 15 ... 91
Enquire Here

Frequently Asked Questions

SOCLA's M & MI Systems are membrane non-return valves designed to prevent backflow in fluid systems. They are known for their reliability and silent operation, making them ideal for installations prone to water hammer.

These valves utilize a flexible membrane that opens under forward flow and closes to prevent reverse flow, ensuring unidirectional movement of fluids without mechanical moving parts.

They are ideal for booster pumps, sprinkler systems, motor or electric pump units, compressed air circuits, and installations with variable flow pumps or pulsatory operation.

The operating temperature ranges from -10°C to 60°C, with permissible operating pressures varying by model and medium. For specific details, refer to the technical datasheets.

Materials include cast iron or aluminum bodies, stainless steel seats, and NR (natural rubber) membranes, ensuring durability and compatibility with various fluids.

Yes, SOCLA's membrane non-return valves are designed to operate effectively in any position, providing flexibility in installation.

No, the design of SOCLA's membrane non-return valves ensures they do not generate hammering, resulting in very silent operation.

They are available with female/female BSP threaded connections or flanged connections, depending on the model.

These valves have no mechanical moving parts and feature an anti-incrustation closing system, minimizing maintenance requirements.

Yes, SOCLA's membrane non-return valves are suitable for clear liquids and gases, offering versatility across different applications.

They conform to CE directive 2014/68/UE and have thread connections according to EN 1092-2 standards.

SOCLA membrane check valves are low-maintenance due to their simple design, but periodic inspections are recommended to ensure the membrane remains intact and free of debris.

FAQ

Request more information or Advice

Please feel free to request information and advice using the form below or call us on 0151 547 1221

SOCLA M & MI Systems