3768 Type Inductive Limit Switches

The Type 3768 inductive limit switches, crafted for broad industrial use, facilitate effective functionality across linear control valves via both IEC NAMUR and direct (3277 actuator) connections. Equipped with dual inductive switches exhibiting less than 1% hysteresis and an available solenoid valve, these switches simplify contact adjustment and toggling between NC or NO configurations. They provide straightforward direct mounting to the Type 3277 Pneumatic Actuator and indirect mounting through NAMUR or VDI/VDE 3845 standards.

Key Features

Key features and benefits of 3768 Type Inductive Limit Switches
1

Key Features

They support both direct attachment to the Type 3277 Pneumatic Actuator and indirect attachment via industry standards such as IEC NAMUR and VDI/VDE 3845, ensuring compatibility with a wide range of linear control valves.
2

Key Features

The inclusion of two inductive switches with less than 1% hysteresis guarantees high accuracy and consistent performance, crucial for maintaining operational efficiency and reducing downtime in industrial settings.
3

Key Features

An optional solenoid valve enhances functionality, while the capability for easy contact override and adjustment allows for quick configuration to normally closed (NC) or normally open (NO) positions, facilitating seamless integration into existing systems.

Limit Switch Standards & Stuff

Operation: Linear Actuators
Switching: Inductive
Contacts: Two
Permissible Ambient Temperature: –45 to 80 °C
Explosion Protection: Without, Ex ia, Ex nA
Versions: Solenoid Valve, Stainless Steel Version
Rated Travel Range: 7.5 to 120mm
Certifications: ATEX, CSA, & FM

FAQs

A limit switch is an electromechanical device that operates based on the physical movement or presence of an object. It consists of an actuator mechanically linked to a set of contacts. When an object comes into contact with the actuator, the device operates the contacts to make or break an electrical connection. This action can then be used to control machinery, indicate position, or act as a safety interlock.

The most common types of limit switches include plunger type, rotary type, lever type, and cable type. Each type is designed for specific applications and operates differently based on the movement and the actuation method required for the task.

Limit switches are widely used in industrial automation and manufacturing for control and safety purposes. They are found in conveyor systems, lifting devices, machinery, door mechanisms, and in various positions and end-of-travel limit detection applications.

Selecting the right limit switch involves considering several factors, including the actuation type, the environment (e.g., temperature, moisture, explosive atmospheres), electrical requirements, mounting style, and the physical size. Understanding the specific demands of your application is crucial for choosing the most suitable limit switch.

Yes, there are limit switches designed for outdoor use, featuring weatherproof and waterproof enclosures to protect against environmental elements like dust, water, and extreme temperatures. It's important to choose a limit switch with the appropriate IP (Ingress Protection) rating for outdoor applications.

Installing a limit switch typically involves mounting the switch body securely to a fixed part of the machine and adjusting the actuator or lever so it will be triggered by the moving part of the machine. Wiring must be done according to the electrical specifications, ensuring that the switch is integrated correctly into the control system.

Signs of a failing limit switch include intermittent operation, failure to actuate, or false triggering. Physical signs may include visible damage to the actuator or contacts, and in some cases, an audible click may be absent when the switch should operate.

Yes, limit switches are often used in safety applications to prevent machinery from operating outside of its intended range or to ensure that safety barriers are in place before machinery starts. For these applications, switches with positive opening operations and redundancy may be required for compliance with safety standards.

Yes, limit switches can be integrated with digital control systems. They can be connected to PLCs (Programmable Logic Controllers) or other digital control units to provide input signals based on their actuation. This integration allows for the automation of processes and machinery, enabling precise control over manufacturing operations, real-time monitoring, and the ability to implement complex safety protocols. For successful integration, it's essential to ensure that the electrical characteristics of the limit switch are compatible with the digital control system's input requirements.

Need More Dimensions?

No time for fancy software or your tekkers are just pretty substandard? We offer a full technical drawing service for our actuated valves. The Artists are ready to draw. Tell us what you need.
Request more information or Advice

Please feel free to request information and advice using the form below or call us on 0151 547 1221